Fluoroplastics Insulated Heat Resisting Control Cable
1.Product Characteristic and Application
It is used as connection cable for electric appliances& instruments and transmission cable for automatic control system in controlling and supervising loop of A.Crated voltage of 600/1000V or lower.It has good featureof oil resistance.abrasion resistance. acid & alkali resistance.various chemical reagent(except chloroform)and corrosive gas resistance, aging resistance and badweather resistance etc. It is used as connection cable forelectric appliances & instruments and transmission cablefor automatic control system under bad environment ofextreme temperature mainly in the field of metallurgypower, chemical and petroleum enterprises. F46 or Teflon insulation material is adopted by control cable withfluoroplastics insulation & sheath and high temperatureresistance. It has better heat resistant degree comparedwith common control cable.
2.Executive standard:
enterprise standard and TICW/03-2009
3.Performance for Usage
1.A.C.rated voltage U0/U: 450/750V、600/1000V;
2.Long-term working temperature of cable conduc- tor:
Temperature of fuoroplastic outer protecting layer is 200℃/260℃;
Temperature of PVC outer protecting layer is 105℃.
Temperature of silicon rubber outer protecting layer is 180℃;
3. Temperature for installing cable is no lower than:
0℃ for cable with PVC sheath;
-20℃ for cable with silicon rubber sheath;
-20℃ for cable with fluoroplastic sheath;
4. Bending radius allowed by cable:
It is no less than 6 times that of cable OD for cable withinarmored layer;
It is no less than 12 times that of cable OD for cable witharmored layer or copper tape shielding;
It is no less than 6 times that of cable OD for soft cablewith shielding structure;
lt is no less than 8 times that of cable OD for cable withfluoroplastic insulation and sheath;
4.Type and Description
1.Basic Tvpe and Description
Type | Description |
| KFF | Control cable with fluoroplastic insulation and sheath |
| KFFP | Control cable with fluoroplastic insulation and sheath, copper wire braided shielding |
| KFFR | Control soft cable with fluoroplastic insulation and sheath |
| KFFRP | Control soft cable with fluoroplastic insulation and sheath, copper wire braided shielding |
| KFV | Control cable with fluoroplastic insulation and PVC sheath |
| KFVP | Control cable with fluoroplastic insulation, PVC sheath, copper wire braided shielding |
| KFVR | Control soft cable with fluoroplastic insulation and PVC sheath |
| KFVRP | Control soft cable with fluoroplastic insulation, PVC sheath, copper wire braided shielding |
KFV22 | Control cable with fluoroplastic insulation, PVC sheath, steel tape armor |
KFVP22 | Control cable with fluoroplastic insulation, PVC sheath, steel tape armor, copper wire braided shielding |
KFVR22 | Control soft cable with fluoroplastic insulation, PVC sheath, steel tape armor |
KFVRP22 | Control soft cable with fluoroplastic insulation, PVC sheath, steel tape armor, copper wire braided shieldin |
KFG | Control cable with fluoroplastic insulation, silicon rubber sheath |
KFGP | Control cable with fluoroplastic insulation, silicon rubber sheath, copper wire braided shielding |
KFGR | Control soft cable with fluoroplastic insulation, silicon rubber sheath |
KFGRP | Control soft cable with fluoroplastic insulation, silicon rubber sheath, copper wire braided shielding |
| KFG22 | Control cable with fluoroplastic insulation, silicon rubber sheath, steel tape armor |
2. Type-naming Indication

5.Codes Meaning

Note: we also produce cable with special specification and type according to the requirement of customer.
6. The figure of cable structure

7.Specification of Cable in Following Table

8. Main TechnicalIndices


Tell:+86-152-6220-7107
Email: jinxincable@yzjxdl.com
Website: www.yzjxdl.com
FaceBook: JX Cable
whatsapp: http://wa.me/8615262207107