LSOH Flame Retardant Control Cable
1.Scope ofapplication
t is used for supervising and controlling return circuit of ratedvoltage 450/750V or lower with demand on low smoke, lownalogen and flame retardance.
2.Executive standard:
enterprise standard and GB9330-2008standardfor reference
3.Working Condition
1: Rated voltage: 450/750V
2: Long-term working temperature allowed by cable is 70C.
3: Ambient temperature for installing cable shall be no lowerthan 0C.Recommended bending radius:
It shall be no less than 12 times that of cable O.D for armoredcable with copper tape shielding structure and 6 times that ofcable O.D for cable with other structure.
4.Type and Description
Type and Description in table 1
table1
Type | Description |
| DDZ-KVV | Control cable with Cu core, low smoke & halogen, flame retardant, PVC insulation and sheath |
| DDZ-KVVP | Control cable with Cu core, low smoke & halogen, flame retardant, PVC insulation and sheath, copper wire braided shielding |
| DDZ-KVVR | Control soft cable with Cu core, low smoke & halogen,flame retardant, PVC insulation and sheath |
| DDZ -KVVRP | Control soft cable with Cu core, low smoke & halogen, flame retardant, PVC insulation and sheath, copperwire braided shielding |
| DDZ-KVVP2 | Control cable with Cu core, low smoke & halogen, flame retardant, PVC insulation and sheath, coppertape wrapped shielding |
| DDZ-KVVP22 | Copper core low smoke and low halogen flame retardant PVC insulated and sheathed copperwire woven shield steeltape armored control cable |
| DDZ-KVV32 | Control cable with Cu core, low smoke & halogen,flame retardant, PVC insulation and sheath, steel wirearmor |
Remark:DDZ’ means low smoke & halogen,flame retardant
2.Explanation of Main Noun Term
Low smoke: under stipulated testing conditions, smoke out ofdecomposition with heat or emission in firing is less.which conforms to stipulated indices.
Low halogen: under stipulated testing conditions, HCI content ofsmoke emitted in firing is less which conforms tostipulated indices.
Flame retardant: under stipulated testing conditions, the testedsample is fired.After removing from source,flamespreads within stimulated range, remnant flame willgo out on itself within stipulated time.
5.Specification Scope in Table 2

6.Main TechnicalIndices
1. performance indices of low smoke & halogen and lame retardanceSmoke density test: min. light-penetration ratio is 2 40%.Hcl emission value shall be no more than 100mg/g.
2. Conductor DC resistance value & volage withstand stress at 20℃

Tell:+86-152-6220-7107
Email: jinxincable@yzjxdl.com
Website: www.yzjxdl.com
FaceBook: JX Cable
whatsapp: http://wa.me/8615262207107