Shielding Cable for Computer Application ( Cable for DCSSystem Application
1.Scope ofapplication
lt is used as connection cable of inspection devices and instrumentswith high demand on interference resis tant performance in computernetwork and control sys- tem.
2.Executive standard:
TICW/06-2009 or BS5308 standard for reference
3.Performance for Usage
1: AC rated voltageU./U: 300/500V. Long term work- ing temperatureof cable conductor is 70℃ & 105℃ for cable with PVC insulation,70℃ for cable with PE insula-tion and 90℃ for cable with XLPEinsulation.(XLPE insu- lation includes silane XLPE & irradiationXLPE insulation.)
2: Min. environment temperature is -40℃ for fixed laying and-15℃for non-fixed laying. Environment tem-perature shall be no lessthan 0℃ for installing.
3: Min.bending radius allowed by cable is no less than 6 timesthat of cable OD for non-armored soft cable or braided shieldingcable and 12 times that of cable OD for cable with metallic tapewrapped shielding or steel wire/steel tape armor.
4.Basic Type and Description
5.Type, Description and De inition
Insulation or sheath material:
Y means PE extruded insulation or sheath
V means PVC extruded insulation or sheath
YJ means XLPE extruded insulation
Flame retardant performance category:
ZRA: category A (the best)
ZRB: category B
ZRC & ZR: category C
Prefix“ZRA-”、“ZRB-”、“ZRC or ZR”is added tothe original type of fiame retardant cable.
Armor structure:
22 means steel tape armor, PVC outer sheath
23 means steel tape armor, PE outer sheath
32 means round galvanized low carbon steel wirewrapping, armor, PVC outer sheath
33 means round galvanized low carbon steel wirewrapping, armor, PE outer sheathShielding material:
P means copper wire braiding
P1 means tinned copper wire braiding
P2 means copper-plastic compound tape wrapping
P3 means aluminum- plastic compound tape wrap-
pingstructure of conductor:A means single conductor (omitted in type)B means 7 stranded conductor (“B”shall be addedafter specification)
C means multi-stranded conductor
6.Specification Scope
Pair No.: 1~24 pairs
Core No. per pair: 2 cores (equal to 2 wire group ) or 3 cores(equal to 3 wire group)
Cross section of conductor: 0.5mm² 、0.75mm² 、1.0mm²、1.5mm²、2.5mm²
7.Main Technical Parameter
1、DC Resistance of Conductor at 20C
2、Insulation Resistance at 20C
3、Cable shall endure A.C. voltage test of 1500V under powerfrequency for 1min without puncture of insulation. And testingtemperature is environment temperature.
Tell:+86-152-6220-7107
Email: jinxincable@yzjxdl.com
Website: www.yzjxdl.com
FaceBook: JX Cable
whatsapp: http://wa.me/8615262207107